S100 Standard Drive Contact us Features 1. Strong Performance Powerful sensorless control Starting torque of 200%/0.5Hz is produced and provides robust power in the low speed region. Selectable rotary/standstill auto-tuning Standstill auto-tuning is equipped to find motor constants without rotation under conditions where the system is installed or the motor cannot rotate. Flying start function Inverter capable of quick, reliable, and smooth restart into bi-directional rotating loads. 2. Space efficient design Side by side installation Minimized distance between products enables control panel size reduction when installing multiple AC Drives Smaller Size Main parts are optimally arranged inside through the use of thermal radiation analysis and 3-dimensional design to reduce the dimensions by up to 60% (volume based) compared to the previous product (iG5A) 3. Standard Compliance Built-in DC reactor Effective in improving power factors and decreasing THD ※ 3-phase 400V 30~75kW Built-in EMC filter Meets the electrical noise reduction regulation Related standards: Certified 2nd Environment/Category C3 (Class A) CE standard ※ C2 : 1-phase 200V 0.4~2.2kW ※ C3 : 3-phase 400V 0.4~75kW Global compliance (UL, CE) Global standard compliance ※ UL, CE, Gost, C-tick and cUL Dual rating operation Designed to choose between heavy and normal duty operations Overload capacity ※ Heavy duty operation : 150% of rated current, 60 seconds ※ Normal duty operation : 120% of rated current, 60 seconds Various field networks Able to deal with a variety of field networks easy maintenance and mounting. Various field bus options Profibus, Ethernet IP, Modbus TCP, CANopen Easy to install and use 4. Safety Function Built-in Safety Torque Off (STO) The Safety input function meets EN ISO 13849-1 PLd and EN 61508 SIL2 (En 60204-1, stop category 0) This feature is equipped and meets current safety standards 5. Suitable for Users Simple cooling fan replacement Replaceable fan without complete disassembly Smart copier 1. Smart copier allows users to download & upload the parameters from/to S100 without AC input power. 2. Customized main firmware is able to be downloaded to S100 using Smart copier. 3. Firmware of main control and I/O saved in Smart copier can be downloaded to S100 Multi-keypad function A single LCD keypad can be used to set up the parameters of a RS485 connected drive LCD keypad (same as iS7 model) is used to easily set up parameters. Parameters can be copied to other drives Multi language support will be available Conduit option S100 meets UL type 1 with this option. Flange option With this option, S100 allows its heatsink to be installed outside of the panel for a better cooling system. Frame Design Type Designation Specification 1-Phase 200V (0.4~2.2kW) 3-Phase 200V (0.4~15kW) LSLV ㅁㅁㅁㅁ S100-1 ㅁㅁㅁㅁ0004000800150022 Motor RatingHeavy Duty(HD)[HP]0.51.02.03.0 [kW]0.40.751.52.2 Heavy Duty(HD)[HP]1.02.03.05.0 [kW]0.751.52.23.7 Output RatingCapacity [kVA]Heavy Duty(HD)1.01.93.04.2 Normal Duty(ND)1.22.33.84.6 Rated CurrentHeavy Duty(HD)2.55.08.011.0 Normal Duty(ND)3.16.09.612.0 Frequency [Hz]0~400Hz (IM Sensorless : 0~120[Hz]) Voltage [V]3-phase 200~240V Input RatingVoltage [V]-phase 200~240VAC (-15% ~ +10%) Frequency [Hz]50~60Hz ( ±5%) Rated Current [A]Heavy Duty(HD)4.493.15.621.7 Normal Duty(ND)5.811.719.724.0 Weight [kg]0.9 (1.14)1.3 (1.76)1.5 (1.76)2.0 (2.22) 3-Phase 400V (0.4~22kW) LSLV ㅁㅁㅁㅁ S100-2 ㅁㅁㅁㅁ0004000800150022003700400055007501100150 Motor RatingHeavy Duty(HD)[HP]0.51.02.03.05.05.47.510.015.020.0 [kW]0.40.751.52.23.74.05.57.511.015.0 Heavy Duty(HD)[HP]1.02.03.05.05.47.510.015.020.025.0 [kW]0.751.52.23.74.05.57.511.015.018.5 Output RatingCapacity [kVA]Heavy Duty(HD)1.01.93.04.26.16.59.112.217.522.9 Normal Duty(ND)1.22.33.84.66.96.911.415.221.326.3 Rated Current [3-Phase input] (A)Heavy Duty(HD)2.55.08.011.016.017.024.032.046.060.0 Normal Duty(ND)3.16.09.612.018.018.030.040.056.069.0 Rated Current [Single-Phase input] (A)Heavy Duty(HD)1.52.84.66.18.89.313.018.026.033.0 Normal Duty(ND)1.83.35.76.69.99.916.022.031.038.0 Frequency [Hz]0~400Hz (IM Sensorless : 0~120[Hz]) Voltage [V]3-phase 200~240V Input RatingVoltage [V]3-Phase 200~240VAC (-15%~+10%) Single-Phase 200~240VAC (-5%~+10%) Frequency [Hz]50~60Hz (±5%) (In case of single phase input, input frequency is only 60Hz (±5%)) Rated Current [A]Heavy Duty(HD)2.24.98.411.817.518.525.834.950.866.7 Normal Duty(ND)3.06.310.813.119.419.432.744.262.377.2 Weight [kg]0.90.91.31.52.02.03.33.34.67.1 3-Phase 400V (30~75kW) LSLV ㅁㅁㅁㅁ S100-4 ㅁㅁㅁㅁ000400080015002200370040005500750110015001850220 Motor RatingHeavy Duty(HD)[HP]0.51.02.03.05.05.47.510.015.020.025.030.0 [kW]0.40.751.52.23.74.05.57.511.015.018.522.0 Heavy Duty(HD)[HP]1.02.03.05.05.47.510.015.020.025.030.040.0 [kW]0.751.52.23.74.05.57.511.015.018.522.030.0 Output RatingCapacity [kVA]Heavy Duty(HD)1.01.93.04.26.16.59.112.218.322.929.734.3 Normal Duty(ND)1.52.43.95.37.67.612.217.522.929.033.544.2 Rated Current [3-Phase input] (A)Heavy Duty(HD)1.32.54.05.58.09.012.016.024.030.039.045.0 Normal Duty(ND)2.03.15.16.910.010.016.023.030.038.044.058.0 Rated Current [Single-Phase input] (A)Heavy Duty(HD)0.81.52.33.14.85.47.19.515.018.023.027.0 Normal Duty(ND)1.31.93.03.95.95.99.514.018.023.027.035.0 Frequency [Hz]0~400Hz (IM Sensorless : 0~120[Hz]) Voltage [V]3-phase 200~240V Input RatingVoltage [V]3-Phase 200~240VAC (-15%~+10%) Single-Phase 200~240VAC (-5%~+10%) Frequency [Hz]50~60Hz ( ±5%) (In case of single phase input, input frequency is only 60Hz (±5%)) Rated Current [A]Heavy Duty(HD)1.12.44.25.98.79.812.917.526.533.443.650.7 Normal Duty(ND)2.03.35.57.510.810.817.525.433.442.549.565.7 Weight [kg]0.9 (1.18)0. (1.18)1.3 (1.77)1.5 (1.80)2.0 (2.23)2.0 (2.23)3.33.44.64.87.57.5 More Information LSLV ㅁㅁㅁㅁ S100-4 ㅁㅁㅁㅁ03000370045005500750 Motor RatingHeavy Duty(HD)[HP]40.050.060.075.0100.0 [kW]30.037.045.055.075.0 Heavy Duty(HD)[HP]50.060.075.0100.0120.0 [kW]37.045.055.075.090.0 Output RatingCapacity [kVA]Heavy Duty(HD)46576984116 Normal Duty(ND)556778106126 Rated Current [3-Phase input] (A)Heavy Duty(HD)61.075.091.0110152.0 Normal Duty(ND)7591107142169.0 Rated Current [Single-Phase input] (A)Heavy Duty(HD)3239475778 Normal Duty(ND)3947557387 Frequency [Hz]0~400Hz (IM Sensorless : 0~120[Hz]) Voltage [V]3-phase 380~480V Input RatingVoltage [V]3-Phase 380~480VAC (-15%~+10%) Single-Phase 200~240VAC (-5%~+10%) Frequency [Hz]50~60Hz ( ±5%) (In case of single phase input, input frequency is only 60Hz (±5%)) Rated Current [A]Heavy Duty(HD)56.069.085.0103.0143.0 Normal Duty(ND)69.085.0100.0134.0160.0 Weight [kg]25.834.434.441.843.8
| 32 | 39 |
|---|---|
| 47 | 57 | 55 |
| 57 | 69 |
| 67 | 78 |
| 73 | 87 |
| 84 | 116 |
| 91 | 107 |
| 106 | 126 |
| 142 | 169.0 |
| 0.8 | 1.5 |
| 0.9 | 1.3 |
| 1.0 | 2.0 |
| 1.1 | 2.4 |
| 1.3 | 2.5 |
| 1.5 | 2.2 | 2.8 | 2.0 |
| 1.9 | 3.0 |
| 2.0 | 3.3 |
| 2.2 | 3.7 | 4.9 |
| 2.3 | 3.8 | 3.1 |
| 2.4 | 3.9 |
| 2.5 | 5.0 |
| 3.0 | 5.0 |
| 3.1 | 5.1 |
| 3.3 | 5.7 | 4.6 | 5.5 |
| 3.4 | 4.6 |
| 3.7 | 4.0 |
| 3.9 | 5.9 |
| 4.0 | 5.5 |
| 4.2 | 6.1 | 5.9 |
| 4.4 | 93. |
| 4.6 | 6.9 | 6.1 |
| 4.8 | 5.4 | 7.5 |
| 5.3 | 7.6 |
| 5.4 | 7.5 |
| 5.5 | 7.5 |
| 5.9 | 9.5 |
| 6.0 | 9.6 |
| 6.3 | 10.8 |
| 6.5 | 9.1 |
| 6.6 | 9.9 |
| 6.9 | 11.4 | 10.0 |
| 7.1 | 9.5 |
| 7.5 | 11.0 | 10.8 |
| 7.6 | 12.2 |
| 8.0 | 11.0 | 9.0 |
| 8.4 | 11.8 |
| 8.7 | 9.8 |
| 8.8 | 9.3 |
| 9.9 | 16.0 |
| 0.75 | 1.5 |
| 0008 | 0015 |
| 0022 | 0037 |
| 0040 | 0055 |
| 0075 | 0110 |
| 0150 | 0185 |
| 0370 | 0450 |
| 0550 | 0750 |
| 10.0 | 15.0 | 16.0 |
| 10.8 | 17.5 |
| 11.0 | 15.0 |
| 11.7 | 19.7 |
| 12.0 | 18.0 | 16.0 |
| 12.2 | 17.5 | 18.3 |
| 12.9 | 17.5 |
| 13.0 | 18.0 |
| 13.1 | 19.4 |
| 14.0 | 18.0 |
| 15.0 | 18.5 | 18.0 |
| 15.2 | 21.3 |
| 15.6 | 21.7 |
| 16.0 | 17.0 |
| 17.5 | 18.5 | 22.9 |
| 18.0 | 30.0 |
| 18.5 | 22.0 |
| 19.4 | 32.7 |
| 20.0 | 25.0 |
| 22.0 | 31.0 |
| 22.9 | 29.7 |
| 23.0 | 30.0 | 27.0 |
| 24.0 | 32.0 | 30.0 |
| 25.4 | 33.4 |
| 25.8 | 34.9 |
| 26.0 | 33.0 |
| 26.5 | 33.4 |
| 29.0 | 33.5 |
| 30.0 | 40.0 |
| 37.0 | 45.0 |
| 38.0 | 44.0 |
| 39.0 | 45.0 |
| 40.0 | 56.0 |
| 41.8 | 43.8 |
| 42.5 | 49.5 |
| 43.6 | 50.7 |
| 44.2 | 62.3 |
| 45.0 | 55.0 |
| 46.0 | 60.0 |
| 50.0 | 60.0 |
| 50.8 | 66.7 |
| 55.0 | 75.0 |
| 56.0 | 69.0 |
| 61.0 | 75.0 |
| 75.0 | 100.0 | 90.0 |
| 85.0 | 103.0 | 100.0 |
| 91.0 | 110 |
| [HP] | 0.5 | 40.0 |
| [kW] | 0.4 | 0.75 | 30.0 | 37.0 |
| 134.0 | 160.0 |
| ※ C2 | 1-phase 200V 0.4~2.2kW |
| ※ C3 | 3-phase 400V 0.4~75kW |
| 0.(1.18) | 1.3(1.77) |
| 1.3(1.76) | 1.5(1.76) |
| 1.5(1.80) | 2.0(2.23) |
| 2.0(2.23) | 3.3 |
| Voltage [V] | 3-phase 200~240V | 3-phase 380~480V |
| Weight [kg] | 0.9(1.14) | 0.9(1.18) | 25.8 |
| Input Rating | Voltage [V] | -phase 200~240VAC (-15% ~ +10%) | Voltage [V] | 3-Phase 200~240VAC (-15%~+10%)Single-Phase 200~240VAC (-5%~+10%) | Voltage [V] | 3-Phase 380~480VAC (-15%~+10%)Single-Phase 200~240VAC (-5%~+10%) |
| Motor Rating | HeavyDuty(HD) |
| RatedCurrent | Heavy Duty(HD) |
| HeavyDuty(HD) | [HP] |
| Output Rating | Capacity[kVA] |
| Frequency [Hz] | 0~400Hz (IM Sensorless : 0~120[Hz]) | 50~60Hz ( ±5%) | 50~60Hz (±5%)(In case of single phase input, input frequency is only 60Hz (±5%)) | 50~60Hz ( ±5%)(In case of single phase input, input frequency is only 60Hz (±5%)) |
| Heavy Duty(HD) | 1.0 | 46 |
| Normal Duty(ND) | 1.2 | 3.1 | 5.8 | 1.8 | 3.0 | 1.5 | 2.0 | 1.3 | 55 | 75 | 39 | 69.0 |
| Thương hiệu | LS Electric |
| RatedCurrent [A] | Heavy Duty(HD) |
| Rated Current [A] | Heavy Duty(HD) |
| Related standards | Certified 2nd Environment/Category C3 (Class A) CE standard |
| ※ Heavy duty operation | 150% of rated current, 60 seconds |
| ※ Normal duty operation | 120% of rated current, 60 seconds |
| RatedCurrent[3-Phase input] (A) | Heavy Duty(HD) |
| Rated Current [3-Phase input] (A) | Heavy Duty(HD) |
| Frequency [Hz]0~400Hz (IM Sensorless | 0~120[Hz]) |
| RatedCurrent[Single-Phase input] (A) | Heavy Duty(HD) |
| LSLV ㅁㅁㅁㅁ S100-1 ㅁㅁㅁㅁ | 0004 |
| LSLV ㅁㅁㅁㅁ S100-2 ㅁㅁㅁㅁ | 0004 |
| LSLV ㅁㅁㅁㅁ S100-4 ㅁㅁㅁㅁ | 0004 | 0300 |
| Rated Current[Single-Phase input] (A) | Heavy Duty(HD) |
Standard Drive Contact us Features 1. Strong Performance Powerful sensorless control Starting torque of 200%/0.5Hz is produced and provides robust power in the low speed region. Selectable rotary/standstill auto-tuning Standstill auto-tuning is equipped to find motor constants without rotation under conditions where the system is installed or the motor cannot rotate. Flying start function Inverter capable of quick, reliable, and smooth restart into bi-directional rotating loads. 2. Space efficient design Side by side installation Minimized distance between products enables control panel size reduction when installing multiple AC Drives Smaller Size Main parts are optimally arranged inside through the use of thermal radiation analysis and 3-dimensional design to reduce the dimensions by up to 60% (volume based) compared to the previous product (iG5A) 3. Standard Compliance Built-in DC reactor Effective in improving power factors and decreasing THD ※ 3-phase 400V 30~75kW Built-in EMC filter Meets the electrical noise reduction regulation Related standards: Certified 2nd Environment/Category C3 (Class A) CE standard ※ C2 : 1-phase 200V 0.4~2.2kW ※ C3 : 3-phase 400V 0.4~75kW Global compliance (UL, CE) Global standard compliance ※ UL, CE, Gost, C-tick and cUL Dual rating operation Designed to choose between heavy and normal duty operations Overload capacity ※ Heavy duty operation : 150% of rated current, 60 seconds ※ Normal duty operation : 120% of rated current, 60 seconds Various field networks Able to deal with a variety of field networks easy maintenance and mounting. Various field bus options Profibus, Ethernet IP, Modbus TCP, CANopen Easy to install and use 4. Safety Function Built-in Safety Torque Off (STO) The Safety input function meets EN ISO 13849-1 PLd and EN 61508 SIL2 (En 60204-1, stop category 0) This feature is equipped and meets current safety standards 5. Suitable for Users Simple cooling fan replacement Replaceable fan without complete disassembly Smart copier 1. Smart copier allows users to download & upload the parameters from/to S100 without AC input power. 2. Customized main firmware is able to be downloaded to S100 using Smart copier. 3. Firmware of main control and I/O saved in Smart copier can be downloaded to S100 Multi-keypad function A single LCD keypad can be used to set up the parameters of a RS485 connected drive LCD keypad (same as iS7 model) is used to easily set up parameters. Parameters can be copied to other drives Multi language support will be available Conduit option S100 meets UL type 1 with this option. Flange option With this option, S100 allows its heatsink to be installed outside of the panel for a better cooling system. Frame Design Type Designation Specification 1-Phase 200V (0.4~2.2kW) 3-Phase 200V (0.4~15kW) LSLV ㅁㅁㅁㅁ S100-1 ㅁㅁㅁㅁ0004000800150022 Motor RatingHeavy Duty(HD)[HP]0.51.02.03.0 [kW]0.40.751.52.2 Heavy Duty(HD)[HP]1.02.03.05.0 [kW]0.751.52.23.7 Output RatingCapacity [kVA]Heavy Duty(HD)1.01.93.04.2 Normal Duty(ND)1.22.33.84.6 Rated CurrentHeavy Duty(HD)2.55.08.011.0 Normal Duty(ND)3.16.09.612.0 Frequency [Hz]0~400Hz (IM Sensorless : 0~120[Hz]) Voltage [V]3-phase 200~240V Input RatingVoltage [V]-phase 200~240VAC (-15% ~ +10%) Frequency [Hz]50~60Hz ( ±5%) Rated Current [A]Heavy Duty(HD)4.493.15.621.7 Normal Duty(ND)5.811.719.724.0 Weight [kg]0.9 (1.14)1.3 (1.76)1.5 (1.76)2.0 (2.22) 3-Phase 400V (0.4~22kW) LSLV ㅁㅁㅁㅁ S100-2 ㅁㅁㅁㅁ0004000800150022003700400055007501100150 Motor RatingHeavy Duty(HD)[HP]0.51.02.03.05.05.47.510.015.020.0 [kW]0.40.751.52.23.74.05.57.511.015.0 Heavy Duty(HD)[HP]1.02.03.05.05.47.510.015.020.025.0 [kW]0.751.52.23.74.05.57.511.015.018.5 Output RatingCapacity [kVA]Heavy Duty(HD)1.01.93.04.26.16.59.112.217.522.9 Normal Duty(ND)1.22.33.84.66.96.911.415.221.326.3 Rated Current [3-Phase input] (A)Heavy Duty(HD)2.55.08.011.016.017.024.032.046.060.0 Normal Duty(ND)3.16.09.612.018.018.030.040.056.069.0 Rated Current [Single-Phase input] (A)Heavy Duty(HD)1.52.84.66.18.89.313.018.026.033.0 Normal Duty(ND)1.83.35.76.69.99.916.022.031.038.0 Frequency [Hz]0~400Hz (IM Sensorless : 0~120[Hz]) Voltage [V]3-phase 200~240V Input RatingVoltage [V]3-Phase 200~240VAC (-15%~+10%) Single-Phase 200~240VAC (-5%~+10%) Frequency [Hz]50~60Hz (±5%) (In case of single phase input, input frequency is only 60Hz (±5%)) Rated Current [A]Heavy Duty(HD)2.24.98.411.817.518.525.834.950.866.7 Normal Duty(ND)3.06.310.813.119.419.432.744.262.377.2 Weight [kg]0.90.91.31.52.02.03.33.34.67.1 3-Phase 400V (30~75kW) LSLV ㅁㅁㅁㅁ S100-4 ㅁㅁㅁㅁ000400080015002200370040005500750110015001850220 Motor RatingHeavy Duty(HD)[HP]0.51.02.03.05.05.47.510.015.020.025.030.0 [kW]0.40.751.52.23.74.05.57.511.015.018.522.0 Heavy Duty(HD)[HP]1.02.03.05.05.47.510.015.020.025.030.040.0 [kW]0.751.52.23.74.05.57.511.015.018.522.030.0 Output RatingCapacity [kVA]Heavy Duty(HD)1.01.93.04.26.16.59.112.218.322.929.734.3 Normal Duty(ND)1.52.43.95.37.67.612.217.522.929.033.544.2 Rated Current [3-Phase input] (A)Heavy Duty(HD)1.32.54.05.58.09.012.016.024.030.039.045.0 Normal Duty(ND)2.03.15.16.910.010.016.023.030.038.044.058.0 Rated Current [Single-Phase input] (A)Heavy Duty(HD)0.81.52.33.14.85.47.19.515.018.023.027.0 Normal Duty(ND)1.31.93.03.95.95.99.514.018.023.027.035.0 Frequency [Hz]0~400Hz (IM Sensorless : 0~120[Hz]) Voltage [V]3-phase 200~240V Input RatingVoltage [V]3-Phase 200~240VAC (-15%~+10%) Single-Phase 200~240VAC (-5%~+10%) Frequency [Hz]50~60Hz ( ±5%) (In case of single phase input, input frequency is only 60Hz (±5%)) Rated Current [A]Heavy Duty(HD)1.12.44.25.98.79.812.917.526.533.443.650.7 Normal Duty(ND)2.03.35.57.510.810.817.525.433.442.549.565.7 Weight [kg]0.9 (1.18)0. (1.18)1.3 (1.77)1.5 (1.80)2.0 (2.23)2.0 (2.23)3.33.44.64.87.57.5 More Information LSLV ㅁㅁㅁㅁ S100-4 ㅁㅁㅁㅁ03000370045005500750 Motor RatingHeavy Duty(HD)[HP]40.050.060.075.0100.0 [kW]30.037.045.055.075.0 Heavy Duty(HD)[HP]50.060.075.0100.0120.0 [kW]37.045.055.075.090.0 Output RatingCapacity [kVA]Heavy Duty(HD)46576984116 Normal Duty(ND)556778106126 Rated Current [3-Phase input] (A)Heavy Duty(HD)61.075.091.0110152.0 Normal Duty(ND)7591107142169.0 Rated Current [Single-Phase input] (A)Heavy Duty(HD)3239475778 Normal Duty(ND)3947557387 Frequency [Hz]0~400Hz (IM Sensorless : 0~120[Hz]) Voltage [V]3-phase 380~480V Input RatingVoltage [V]3-Phase 380~480VAC (-15%~+10%) Single-Phase 200~240VAC (-5%~+10%) Frequency [Hz]50~60Hz ( ±5%) (In case of single phase input, input frequency is only 60Hz (±5%)) Rated Current [A]Heavy Duty(HD)56.069.085.0103.0143.0 Normal Duty(ND)69.085.0100.0134.0160.0 Weight [kg]25.834.434.441.843.8