Liên hệ
Sản phẩm cần báo giá theo số lượng, công suất hoặc dự án. Gửi yêu cầu để được tư vấn nhanh.
Tổng quan
iP5A Fan and Pump Drive Contact us Features Dual PID When additional PID control or cascade PID control is required, dual PID provide users with various uses of the system with only iP5A. Multi Motor Control The built-in algebra control function enables an inverter to control motors without a controller so that user can take advantage of energy-saving and lower costs. Sleep and Wake-Up The built-in energy saving function makes the inverter stop automatically when the capacity is too low. Pre-Heater The built-in pre-heater function prevents motor damage and inverter break-down caused from humidity. Flying Start When the inverter drives many ventilators or when the fan in a big load system turns due to a natural displacement, iP5A operates the motor by automatically searching for the motor speed. Auto energy saving iP5A provides the auto energy saving function by an optimal flux control which minimizes energy loss caused by load change. Improved Management from Instant Power-off and Power Dip Generation During the power dip or instant power-off, which is generated by lightening, ground fault, and power-failure, loads still keep the mechanical energy and this energy flows back to inverter by regeneration. The power-failure guarantee time is extended by using this electrical character of the inverter. Constant and Stable Performance (24 hours 365 days) Regardless of outside alteration such as input voltage variation by load change or weather effect, iP5A can handle motor and load with best performance. Safety Stop When unexpected power-failure blocks the power supply, the inverter stops the motor by using energy of the load that prevents reoccurrence of accidents (Parameter setting is required). Type Designation Specification 3-phase 200V Class (0.75~30kW) 3-phase 400V Class (0.75~90kW) Model Number (SVㅁㅁㅁiP5A-2)008015022037055075110150185220300 Capacity [kVA] 1)1.93.04.66.16.112.217.522.928.233.543.8 Output ratingsFan or pump loadMotor rating 2)(HP)12357.5101520253040 (kW)0.751.52.23.75.57.5111518.52230 Current [A]581216243246607488115 (110% over current)110% 1 Minute (Normal Duty) General loadMotor rating(HP)0.512357.51015202530 (kW)0.40.751.52.23.75.57.5111518.522 Current [A]2.5581217233344546884 (150% over current)150% 1 Minute (Heavy Duty) Frequency0.01~120 Hz Voltage200~230V 3) Input ratingsVoltage3Ø200~230V (-15%~+10%) Frequency50/60 Hz (± 5%) Protection degreeIP20 / UL Type1IP00 / UL Open 4) Weight [kg (lbs.)]4.1 (9.0)4.2 (9.3)4.2 (9.3)4.9 (10.8)4.9 (10.8)6 (13.2)6 (13.2)13 (28.7)13.5 (29.8)20 (44.1)20 (44,1) 3-phase 400V Class (110~450kW) Model Number (SVㅁㅁㅁiP5A-4)008015022037055075110150185220300370450550750900 Capacity [kVA] 1)2.03.24.86.49.612.719.123.931.135.948.659.872.587.6121.1145.8 Output ratingsFan or pump loadMotor rating 2)(HP)12357.5101520253040506075100125 (kW)0.751.52.23.75.57.5111518.522303745557590 Current [A]2.5468121624303945617591110152183 (110% over current)110% 1 Minute (Normal Duty) General loadMotor rating(HP)0.512357.5101520253040506075100 (kW)0.40.751.52.23.75.57.5111518.5223037455575 Current [A]1.252.5468.8121622/2428/3034/3944/45----- (150% over current)150% 1 Minute (Heavy Duty) Frequency0.01~120 Hz Voltage380~480V 3) Input ratingsVoltage3Ø380~480V (-15%~+10%) Frequency50/60 Hz (± 5%) Protection degreeIP20 / UL Type1IP00 / UL Open 4) Weight [kg (lbs.)]Standard Type4.1 (9.0)4.2 (9.3)4.2 (9.3)4.9 (10.8)4.9 (10.8)6 (13.2)6 (13.2)12.5 (27.6)13 (28.7)20 (44.1)20 (44.1)27 (59.5)27 (59.5)29 (64)43 (94.8)42 (92.6) Built-in DCL Type-------19.5 (43.9)19.5 (42.9)26.5 (58.3)26.5 (58.3)39 (86)40 (88.2)42 (92.6)67 (147.4)68 (149.9) 3-phase 600V Class (5.5~110kW) Model Number (SVㅁㅁㅁiP5A-2)11001320160022002800315037504500 Capacity [kVA] 1)178210259344436488582699 Output ratingsFan or pump loadMotor rating 2)(HP)150200250350400500600700 (kW)110132160220280315375450 Current [A]223264325432547613731877 (110% over current)110% 1 Minute (Normal Duty) General loadMotor rating(HP)125150200250350400500600 (kW)90110132160220280315375 Current [A]183223264325432547613731 (150% over current)150% 1 Minute (Heavy Duty) Frequency0.01~120 Hz Voltage380~480V 3) Input ratingsVoltage3Ø380~480V (-15%~+10%) Frequency50/60 Hz (± 5%) Protection degreeIP00 / UL Open 4) DCLBuilt-inExternal Option Weight [kg (lbs.)]101 (222.7)101 (222.7)114 (251.3)200 (441.9)200 (441.9)243 (535.7)380 (837.7)380 (837.7) 1) Rated capacity (v 3 X V X I) is based on 220V for 200V class and 460V for 400V class. 2) Indicates the maximum applicable capacity when using a 4-Pole LS motor. 3) Maximum output voltage will not exceed the input voltage. An output voltage less than the input voltage may be programmed if necessary. 4) IP20/UL Type1 with optional conduit, it can be modified to UL Type-1. More Information Model Number (SVㅁㅁㅁiP5A-2)0550751101501852203003704505507509001100 Capacity [kVA] 1)9.612.719.123.931.135.948.659.872.587.6121.1145.8178 Output ratingsFan or pump loadMotor rating 2)(HP)7.5101520253040506075100125150 (kW)5.57.5111518.522303745557590110 Current [A]9121723273443556480104128150 (110% over current)110% 1Minute (Normal Duty) General loadMotor rating(HP)5.57.5101520253040506075100125 (kW)3.75.57.5111518.522303745557590 Current [A]6.19121723273443556480104128 (150% over current)150% 1 Minute (Heavy Duty) Frequency0.01~120 Hz Voltage525 ~600V 3) Input ratingsVoltage3f 525~600V (-15% ~ +10 %) Frequency50/60 Hz (±5 %) Protection degreeIP20 / UL Type1IP00 / UL Open 4) Weight [kg (lbs.)]6.5 (14.4)7.0 (15.5)7.0 (15.5)11.7 (25.8)11.7 (25.8)18.9 (41.7)18.9 (41.7)32 (70.65)32 (70.65)32 (70.65)46 (101.5)46 (101.5)101 (223)
| 1 | 2 |
|---|---|
| 3 | 5 |
| 4 | 6 |
| 5 | 8 |
| 6 | 8.8 |
| 8 | 12 |
| 9 | 12 |
| 11 | 15 |
| 12 | 17 | 16 |
| 15 | 20 | 18.5 |
| 16 | 24 |
| 17 | 23 |
| 22 | 30 |
| 23 | 33 | 27 |
| 25 | 30 |
| 27 | 34 |
| 30 | 39 | 37 |
| 32 | 46 |
| 34 | 43 |
| 37 | 45 |
| 40 | 50 |
| 43 | 55 |
| 44 | 54 |
| 45 | 61 | 55 |
| 55 | 75 | 64 |
| 60 | 74 | 75 |
| 64 | 80 |
| 68 | 84 |
| 75 | 91 | 90 |
| 80 | 104 |
| 88 | 115 |
| 90 | 110 |
| 100 | 125 |
| 104 | 128 |
| 110 | 152 | 132 |
| 128 | 150 |
| 132 | 160 |
| 150 | 185 | 200 |
| 160 | 220 |
| 210 | 259 |
| 220 | 300 | 280 |
| 223 | 264 |
| 250 | 350 |
| 264 | 325 |
| 280 | 315 |
| 315 | 375 |
| 325 | 432 |
| 344 | 436 |
| 370 | 450 |
| 400 | 500 |
| 432 | 547 |
| 488 | 582 |
| 547 | 613 |
| 550 | 750 |
| 600 | 700 |
| 613 | 731 |
| 900 | 1100 |
| 1320 | 1600 |
| 2200 | 2800 |
| 3150 | 3750 |
| 015 | 022 |
| 037 | 055 |
| 075 | 110 |
| 1.5 | 2.2 |
| 2.2 | 3.7 |
| 2.5 | 4 |
| 3.0 | 4.6 |
| 3.2 | 4.8 |
| 3.7 | 5.5 |
| 5.5 | 7.5 |
| 6.4 | 9.6 |
| 7.5 | 10 | 11 |
| DCL | Built-in | External Option |
| (HP) | 0.5 | 125 | 5.5 |
| (kW) | 0.75 | 0.4 | 110 | 90 | 5.5 | 3.7 |
| 0.75 | 1.5 |
| 12.2 | 17.5 |
| 12.7 | 19.1 |
| 18.5 | 22 |
| 22.9 | 28.2 |
| 23.9 | 31.1 |
| 33.5 | 43.8 |
| 35.9 | 48.6 |
| 59.8 | 72.5 |
| 87.6 | 121.1 |
| 145.8 | 178 |
| 22/24 | 28/30 |
| 34/39 | 44/45 |
| 39 (86) | 40 (88.2) |
| Voltage | 200~230V 3) | 380~480V 3) | 525 ~600V 3) |
| 4.1(9.0) | 4.2(9.3) |
| 4.2(9.3) | 4.9(10.8) |
| 6 (13.2) | 12.5 (27.6) |
| 13 (28.7) | 13.5 (29.8) | 20 (44.1) |
| 20 (44.1) | 20 (44,1) | 27 (59.5) |
| 27 (59.5) | 29 (64) |
| 4.9(10.8) | 4.9 (10.8) |
| 42 (92.6) | 67 (147.4) |
| 43 (94.8) | 42 (92.6) |
| Frequency | 0.01~120 Hz | 50/60 Hz (± 5%) | 50/60 Hz (±5 %) |
| 32 (70.65) | 46 (101.5) |
| 4.9 (10.8) | 6 (13.2) |
| 46 (101.5) | 101 (223) |
| 101 (222.7) | 114 (251.3) |
| 19.5 (43.9) | 19.5 (42.9) |
| 243 (535.7) | 380 (837.7) |
| Current [A] | 5 | 2.5 | 1.25 | 223 | 183 | 9 | 6.1 |
| General load | Motor rating |
| Input ratings | Voltage | 3Ø200~230V (-15%~+10%) | Voltage | 3Ø380~480V (-15%~+10%) | Voltage | 3f 525~600V (-15% ~ +10 %) |
| Output ratings | Fan or pump load |
| Motor rating 2) | (HP) |
| Thương hiệu | LS Electric |
| Built-in DCL Type | - |
| Capacity [kVA] 1) | 1.9 | 2.0 | 178 | 9.6 |
| Protection degree | IP20 / UL Type1 | IP00 / UL Open 4) |
| Weight [kg (lbs.)] | 4.1(9.0) | Standard Type | 101 (222.7) | 6.5 (14.4) |
| (110% over current) | 110% 1 Minute (Normal Duty) | 110% 1Minute (Normal Duty) |
| (150% over current) | 150% 1 Minute (Heavy Duty) |
| Model Number (SVㅁㅁㅁiP5A-2) | 008 | 1100 | 055 |
| Model Number (SVㅁㅁㅁiP5A-4) | 008 |
iP5A Fan and Pump Drive Contact us Features Dual PID When additional PID control or cascade PID control is required, dual PID provide users with various uses of the system with only iP5A. Multi Motor Control The built-in algebra control function enables an inverter to control motors without a controller so that user can take advantage of energy-saving and lower costs. Sleep and Wake-Up The built-in energy saving function makes the inverter stop automatically when the capacity is too low. Pre-Heater The built-in pre-heater function prevents motor damage and inverter break-down caused from humidity. Flying Start When the inverter drives many ventilators or when the fan in a big load system turns due to a natural displacement, iP5A operates the motor by automatically searching for the motor speed. Auto energy saving iP5A provides the auto energy saving function by an optimal flux control which minimizes energy loss caused by load change. Improved Management from Instant Power-off and Power Dip Generation During the power dip or instant power-off, which is generated by lightening, ground fault, and power-failure, loads still keep the mechanical energy and this energy flows back to inverter by regeneration. The power-failure guarantee time is extended by using this electrical character of the inverter. Constant and Stable Performance (24 hours 365 days) Regardless of outside alteration such as input voltage variation by load change or weather effect, iP5A can handle motor and load with best performance. Safety Stop When unexpected power-failure blocks the power supply, the inverter stops the motor by using energy of the load that prevents reoccurrence of accidents (Parameter setting is required). Type Designation Specification 3-phase 200V Class (0.75~30kW) 3-phase 400V Class (0.75~90kW) Model Number (SVㅁㅁㅁiP5A-2)008015022037055075110150185220300 Capacity [kVA] 1)1.93.04.66.16.112.217.522.928.233.543.8 Output ratingsFan or pump loadMotor rating 2)(HP)12357.5101520253040 (kW)0.751.52.23.75.57.5111518.52230 Current [A]581216243246607488115 (110% over current)110% 1 Minute (Normal Duty) General loadMotor rating(HP)0.512357.51015202530 (kW)0.40.751.52.23.75.57.5111518.522 Current [A]2.5581217233344546884 (150% over current)150% 1 Minute (Heavy Duty) Frequency0.01~120 Hz Voltage200~230V 3) Input ratingsVoltage3Ø200~230V (-15%~+10%) Frequency50/60 Hz (± 5%) Protection degreeIP20 / UL Type1IP00 / UL Open 4) Weight [kg (lbs.)]4.1 (9.0)4.2 (9.3)4.2 (9.3)4.9 (10.8)4.9 (10.8)6 (13.2)6 (13.2)13 (28.7)13.5 (29.8)20 (44.1)20 (44,1) 3-phase 400V Class (110~450kW) Model Number (SVㅁㅁㅁiP5A-4)008015022037055075110150185220300370450550750900 Capacity [kVA] 1)2.03.24.86.49.612.719.123.931.135.948.659.872.587.6121.1145.8 Output ratingsFan or pump loadMotor rating 2)(HP)12357.5101520253040506075100125 (kW)0.751.52.23.75.57.5111518.522303745557590 Current [A]2.5468121624303945617591110152183 (110% over current)110% 1 Minute (Normal Duty) General loadMotor rating(HP)0.512357.5101520253040506075100 (kW)0.40.751.52.23.75.57.5111518.5223037455575 Current [A]1.252.5468.8121622/2428/3034/3944/45----- (150% over current)150% 1 Minute (Heavy Duty) Frequency0.01~120 Hz Voltage380~480V 3) Input ratingsVoltage3Ø380~480V (-15%~+10%) Frequency50/60 Hz (± 5%) Protection degreeIP20 / UL Type1IP00 / UL Open 4) Weight [kg (lbs.)]Standard Type4.1 (9.0)4.2 (9.3)4.2 (9.3)4.9 (10.8)4.9 (10.8)6 (13.2)6 (13.2)12.5 (27.6)13 (28.7)20 (44.1)20 (44.1)27 (59.5)27 (59.5)29 (64)43 (94.8)42 (92.6) Built-in DCL Type-------19.5 (43.9)19.5 (42.9)26.5 (58.3)26.5 (58.3)39 (86)40 (88.2)42 (92.6)67 (147.4)68 (149.9) 3-phase 600V Class (5.5~110kW) Model Number (SVㅁㅁㅁiP5A-2)11001320160022002800315037504500 Capacity [kVA] 1)178210259344436488582699 Output ratingsFan or pump loadMotor rating 2)(HP)150200250350400500600700 (kW)110132160220280315375450 Current [A]223264325432547613731877 (110% over current)110% 1 Minute (Normal Duty) General loadMotor rating(HP)125150200250350400500600 (kW)90110132160220280315375 Current [A]183223264325432547613731 (150% over current)150% 1 Minute (Heavy Duty) Frequency0.01~120 Hz Voltage380~480V 3) Input ratingsVoltage3Ø380~480V (-15%~+10%) Frequency50/60 Hz (± 5%) Protection degreeIP00 / UL Open 4) DCLBuilt-inExternal Option Weight [kg (lbs.)]101 (222.7)101 (222.7)114 (251.3)200 (441.9)200 (441.9)243 (535.7)380 (837.7)380 (837.7) 1) Rated capacity (v 3 X V X I) is based on 220V for 200V class and 460V for 400V class. 2) Indicates the maximum applicable capacity when using a 4-Pole LS motor. 3) Maximum output voltage will not exceed the input voltage. An output voltage less than the input voltage may be programmed if necessary. 4) IP20/UL Type1 with optional conduit, it can be modified to UL Type-1. More Information Model Number (SVㅁㅁㅁiP5A-2)0550751101501852203003704505507509001100 Capacity [kVA] 1)9.612.719.123.931.135.948.659.872.587.6121.1145.8178 Output ratingsFan or pump loadMotor rating 2)(HP)7.5101520253040506075100125150 (kW)5.57.5111518.522303745557590110 Current [A]9121723273443556480104128150 (110% over current)110% 1Minute (Normal Duty) General loadMotor rating(HP)5.57.5101520253040506075100125 (kW)3.75.57.5111518.522303745557590 Current [A]6.19121723273443556480104128 (150% over current)150% 1 Minute (Heavy Duty) Frequency0.01~120 Hz Voltage525 ~600V 3) Input ratingsVoltage3f 525~600V (-15% ~ +10 %) Frequency50/60 Hz (±5 %) Protection degreeIP20 / UL Type1IP00 / UL Open 4) Weight [kg (lbs.)]6.5 (14.4)7.0 (15.5)7.0 (15.5)11.7 (25.8)11.7 (25.8)18.9 (41.7)18.9 (41.7)32 (70.65)32 (70.65)32 (70.65)46 (101.5)46 (101.5)101 (223)